Brand Name : SRS

Model Number : SRS540

Place of Origin : USA

MOQ : 1 set

Price : Negotiation

Payment Terms : T/T

Supply Ability : in stock

Product name : Optical Chopper Controller

Chopping frequency : 4 Hz to 3.7 kHz

Frequency display : 4-digit, 1 Hz resolution and accuracy

Cable length : 6 ft.

Power : 12 W, 100/120/220/240 VAC, 50/60 Hz

Interfaces : GPIB, RS-232 and Ethernet

Contact Now

SRS Stanford Research Systems Model SRS540 Optical Chopper Controller 4 Hz to 3.7 kHz

Description of SRS Stanford Research Systems SRS540 Optical Chopper Controller

The SR540 chopper will handle all your optical chopping requirements—from simple measurements to dual-beam and intermodulation experiments. The SR540 has a 4-digit frequency display, front-panel frequency control, analog voltage frequency control and two reference outputs with selectable operating modes

The SR540 chopper will handle all your optical chopping requirements—from simple measurements to dual-beam and intermodulation experiments. The SR540 has a 4-digit frequency display, front-panel frequency control, analog voltage frequency control and two reference outputs with selectable operating modes. Two anodized aluminum blades are provided: a 5/6 slot blade for frequencies up to 400 Hz, and a 25/30 slot blade for frequencies up to 3.7 kHz. Reference outputs are provided for frequencies corresponding to each row of slots, as well as the sum and difference frequencies.

Features of SRS Stanford Research Systems SRS540 Optical Chopper Controller

Optical Chopper Applications

Single-Beam Experiment

In this application, a single optical beam is chopped by the outer row of slots, and the reference output from the right BNC is used to lock the lock-in amplifier to the chop frequency. The inner row of slots could also be used, in which case the left BNC would be the reference output. In either case, the REFERENCE MODE switch is in the “up” position.

Dual-Beam Experiment

In this arrangement, the output from a single source is split and chopped at two different frequencies by the two rows of chopper slots. One beam passes through the experiment while the other is used as a reference beam. The beams are recombined and sent to the same detector. Two lock-ins are used to detect the signals at ƒinner, corresponding to the experimental signal, and ƒouter, corresponding to the reference beam. If the detected signal in the experimental arm is ratioed to the detected signal in the control arm, then effects due to changing source intensity and detector efficiency are removed.

Specification of SRS540

Chop frequency 4 Hz to 400 Hz (5/6 slot blade)
400 Hz to 3.7 kHz (25/30 slot blade)
Frequency stability 250 ppm/°C (typ.)
Frequency drift <2 %, 100 Hz < f < 3700 Hz
Phase jitter (rms) 0.2° (50 Hz to 400 Hz)
0.5° (400 Hz to 3.7 kHz)
Frequency display 4-digit, 1 Hz resolution and accuracy
Frequency control 10-turn pot with 3 ranges:
4 Hz to 40 Hz
40 Hz to 400 Hz
400 Hz to 3.7 kHz
Input control voltage 0 to 10 VDC for 0 to 100% of full scale. Control voltage overrides frequency dial.
Reference modes ƒinner, ƒouter, 5 × ƒouter, ƒinner + ƒouter, ƒouter - ƒinner
Dimensions Controller: 7.7" × 1.8" × 5.1" (WHL)
Chopper head: 2.8" × 2.1" × 1.0" (WHL)
Blade diameter 4.04" ±0.002"
Cable length 6 ft.
Power 12 W, 100/120/220/240 VAC, 50/60 Hz
Warranty One year parts and labor on defects in materials and workmanship, 90 days on motor.

Ordering Information for SRS540

SR540 Optical chopper

O5402530 25/30 dual-slot replacement blade

O54056 5/6 dual-slot replacement blade

O5405 5-slot replacement blade

O54030 30-slot replacement blade

O540RCH Replacement chopper head

FAQ:

1.Can you ship order to Canada or Australia?
Yes,we can .We send orders worldwide.

2. What delivery method do you use? and delivery time?

We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.

3. What is your payment term?

100% T/T payment before shipment.

4. How can I ask any other question?

You can contact us online or leave us messages below.

SRS Stanford Research Systems Model SRS540 Optical Chopper Controller 4 Hz to 3.7 kHzSRS Stanford Research Systems Model SRS540 Optical Chopper Controller 4 Hz to 3.7 kHzSRS Stanford Research Systems Model SRS540 Optical Chopper Controller 4 Hz to 3.7 kHz


Product Tags:

Model SRS540 Optical Chopper Controller

      

4 Hz Optical Chopper Controller

      

3.7 kHz Optical Chopper Controller

      
Wholesale SRS Stanford Research Systems Model SRS540 Optical Chopper Controller 4 Hz to 3.7 kHz from china suppliers

SRS Stanford Research Systems Model SRS540 Optical Chopper Controller 4 Hz to 3.7 kHz Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen Meigaolan Electronic Instrument Co. Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)